Plantsight
Corrective action

Open findings across the estate

Every row was derived by the rule engine from a recorded answer or a photo observation the inspector accepted. Nothing here was typed by hand.

84 findings
RuleFindingAssetHazardClassificationScoreDue
R-GM-01
Fixed guard missingphoto
LY/GM-103
Lyndale Packing
Entanglement or crushing at moving partsImmediate danger202026-01-28
R-GM-01
Fixed guard missingphoto
HP/GM-105
Havenport Terminal
Entanglement or crushing at moving partsImmediate danger202025-10-28
R-GM-01
Fixed guard missingphoto
NG/GM-107
Northgate Works
Entanglement or crushing at moving partsImmediate danger202026-05-28
R-GM-01
Fixed guard missingphoto
NG/GM-113
Northgate Works
Entanglement or crushing at moving partsImmediate danger202025-11-28
R-SB-05
Severe thermal rise at a termination
NG/SB-101
Northgate Works
Arc flash / electric shockImmediate danger152026-06-28
R-SB-01
Energised parts reachablephoto
LY/SB-103
Lyndale Packing
Arc flash / electric shockImmediate danger152026-02-28
R-SB-05
Severe thermal rise at a termination
LY/SB-106
Lyndale Packing
Arc flash / electric shockImmediate danger152024-12-28
R-SB-01
Energised parts reachablephoto
NG/SB-107
Northgate Works
Arc flash / electric shockImmediate danger152026-03-28
R-CR-05
Broken wires at or beyond discard criteriaphoto
LY/CR-106
Lyndale Packing
Dropped or swinging loadImmediate danger152026-07-28
R-CR-05
Broken wires at or beyond discard criteriaphoto
NG/CR-107
Northgate Works
Dropped or swinging loadImmediate danger152025-06-28
R-CR-04
Hook twisted, cracked or gouged
LY/CR-103
Lyndale Packing
Dropped or swinging loadImmediate danger102026-04-28
R-CR-01
Hook safety latch missing or defeated
NG/CR-107
Northgate Works
Dropped or swinging loadNon-conforming162025-06-29
R-PV-06
Heavy external corrosion or section lossphoto
NG/PV-104
Northgate Works
Structural failure under loadNon-conforming122026-03-14
R-PV-03
Relief discharge path obstructed
HP/PV-105
Havenport Terminal
Uncontrolled release of stored pressureNon-conforming122025-11-04
R-PV-03
Relief discharge path obstructed
HP/PV-108
Havenport Terminal
Uncontrolled release of stored pressureNon-conforming122025-11-04
R-PV-06
Heavy external corrosion or section lossphoto
HP/PV-108
Havenport Terminal
Structural failure under loadNon-conforming122025-11-11
R-SB-02
Blanking or gland plate missing
NG/SB-101
Northgate Works
Arc flash / electric shockNon-conforming122026-07-05
R-SB-02
Blanking or gland plate missingphoto
LY/SB-103
Lyndale Packing
Arc flash / electric shockNon-conforming122026-03-07
R-SB-02
Blanking or gland plate missing
LY/SB-106
Lyndale Packing
Arc flash / electric shockNon-conforming122025-01-04
R-SB-02
Blanking or gland plate missingphoto
NG/SB-107
Northgate Works
Arc flash / electric shockNon-conforming122026-04-04
R-CR-08
Upper hoist limit inoperative
HP/CR-108
Havenport Terminal
Dropped or swinging loadNon-conforming122026-04-29
R-GM-06
Emergency stop out of reach
HP/GM-102
Havenport Terminal
Entanglement or crushing at moving partsNon-conforming122025-06-11
R-GM-03
Movable guard not interlocked
LY/GM-103
Lyndale Packing
Entanglement or crushing at moving partsNon-conforming122026-02-27
R-GM-06
Emergency stop out of reach
NG/GM-104
Northgate Works
Entanglement or crushing at moving partsNon-conforming122025-11-11
R-GM-06
Emergency stop out of reach
HP/GM-105
Havenport Terminal
Entanglement or crushing at moving partsNon-conforming122025-11-11
R-GM-05
Guard aperture exceeds safe gap
LY/GM-106
Lyndale Packing
Entanglement or crushing at moving partsNon-conforming122026-05-12
R-GM-07
Pull-cord fails along part of its run
NG/GM-110
Northgate Works
Entanglement or crushing at moving partsNon-conforming122026-02-04
R-GM-05
Guard aperture exceeds safe gap
NG/GM-113
Northgate Works
Entanglement or crushing at moving partsNon-conforming122025-12-12
R-PV-08
Support or saddle section loss
HP/PV-102
Havenport Terminal
Structural failure under loadNon-conforming82025-06-11
R-PV-09
Weld seam defect visible
NG/PV-104
Northgate Works
Structural failure under loadNon-conforming82026-03-07
R-PV-04
Isolation valve fitted beneath relief device
HP/PV-111
Havenport Terminal
Uncontrolled release of stored pressureNon-conforming82026-01-27
R-SB-03
No arc-flash or shock-hazard labellingphoto
LY/SB-103
Lyndale Packing
Arc flash / electric shockNon-conforming122026-03-30
R-SB-08
Working space obstructed by stored materialphoto
LY/SB-103
Lyndale Packing
Access, egress and emergency response impairedNon-conforming122026-03-07
R-SB-03
No arc-flash or shock-hazard labellingphoto
NG/SB-107
Northgate Works
Arc flash / electric shockNon-conforming122026-04-27
R-SB-08
Working space obstructed by stored materialphoto
NG/SB-107
Northgate Works
Access, egress and emergency response impairedNon-conforming122026-04-04
R-SB-08
Working space obstructed by stored material
HP/SB-111
Havenport Terminal
Access, egress and emergency response impairedNon-conforming122026-01-04
R-PV-12
Internal inspection overdue
HP/PV-105
Havenport Terminal
Loss of design or inspection traceabilityRecords / traceability92025-12-27
R-SB-12
Enclosure does not secure
NG/SB-101
Northgate Works
Arc flash / electric shockNon-conforming92026-07-12
R-SB-13
Enclosure damage affects ingress protection
NG/SB-104
Northgate Works
Arc flash / electric shockNon-conforming92026-01-27
R-CR-14
Major inspection overdue
NG/CR-104
Northgate Works
Loss of design or inspection traceabilityNon-conforming92026-06-27
R-CR-07
Rope corroded or unlubricatedphoto
LY/CR-106
Lyndale Packing
Dropped or swinging loadNon-conforming92026-08-11
R-CR-07
Rope corroded or unlubricatedphoto
NG/CR-107
Northgate Works
Dropped or swinging loadNon-conforming92025-07-12
R-CR-14
Major inspection overdue
NG/CR-107
Northgate Works
Loss of design or inspection traceabilityNon-conforming92025-08-27
R-GM-10
Stored energy sources not documented
HP/GM-102
Havenport Terminal
Loss of design or inspection traceabilityRecords / traceability92025-06-27
R-GM-10
Stored energy sources not documented
HP/GM-105
Havenport Terminal
Loss of design or inspection traceabilityRecords / traceability92025-11-27
R-PV-10
Data plate missing or unreadablephoto
NG/PV-104
Northgate Works
Loss of design or inspection traceabilityRecords / traceability82026-04-29
R-PV-10
Data plate missing or unreadablephoto
HP/PV-108
Havenport Terminal
Loss of design or inspection traceabilityRecords / traceability82025-12-27
R-PV-10
Data plate missing or unreadable
HP/PV-111
Havenport Terminal
Loss of design or inspection traceabilityRecords / traceability82026-02-26
R-PV-14
Drain inoperable or condensate present
HP/PV-111
Havenport Terminal
Structural failure under loadObservation82026-01-27
R-PV-10
Data plate missing or unreadable
NG/PV-113
Northgate Works
Loss of design or inspection traceabilityRecords / traceability82026-07-27
R-PV-14
Drain inoperable or condensate present
NG/PV-113
Northgate Works
Structural failure under loadObservation82026-06-27
R-SB-06
Thermographic survey overdue
NG/SB-101
Northgate Works
Loss of design or inspection traceabilityRecords / traceability82026-08-27
R-SB-06
Thermographic survey overdue
LY/SB-103
Lyndale Packing
Loss of design or inspection traceabilityRecords / traceability82026-04-29
R-SB-15
Main switch not identified
LY/SB-103
Lyndale Packing
Access, egress and emergency response impairedRecords / traceability82026-03-30
R-SB-06
Thermographic survey overdue
NG/SB-104
Northgate Works
Loss of design or inspection traceabilityRecords / traceability82026-02-26
R-SB-15
Main switch not identified
LY/SB-106
Lyndale Packing
Access, egress and emergency response impairedRecords / traceability82025-01-27
R-SB-06
Thermographic survey overdue
NG/SB-107
Northgate Works
Loss of design or inspection traceabilityRecords / traceability82026-05-27
R-SB-10
Circuit schedule missing or out of date
NG/SB-107
Northgate Works
Loss of design or inspection traceabilityRecords / traceability82026-04-27
R-SB-15
Main switch not identified
NG/SB-107
Northgate Works
Access, egress and emergency response impairedRecords / traceability82026-04-27
R-SB-15
Main switch not identified
LY/SB-109
Lyndale Packing
Access, egress and emergency response impairedRecords / traceability82025-10-28
R-CR-13
Log book not current
HP/CR-102
Havenport Terminal
Loss of design or inspection traceabilityRecords / traceability82026-05-28
R-CR-13
Log book not current
LY/CR-103
Lyndale Packing
Loss of design or inspection traceabilityRecords / traceability82026-05-28
R-CR-13
Log book not current
NG/CR-104
Northgate Works
Loss of design or inspection traceabilityRecords / traceability82026-05-28
R-CR-12
Safe working load not marked
HP/CR-108
Havenport Terminal
Loss of design or inspection traceabilityRecords / traceability82026-05-12
R-GM-15
Spillage or accumulation around the machinephoto
LY/GM-103
Lyndale Packing
Access, egress and emergency response impairedObservation82026-02-11
R-GM-15
Spillage or accumulation around the machinephoto
HP/GM-105
Havenport Terminal
Access, egress and emergency response impairedObservation82025-11-11
R-GM-15
Spillage or accumulation around the machinephoto
NG/GM-107
Northgate Works
Access, egress and emergency response impairedObservation82026-06-11
R-GM-11
No current risk assessment on file
NG/GM-110
Northgate Works
Loss of design or inspection traceabilityRecords / traceability82026-03-29
R-GM-15
Spillage or accumulation around the machinephoto
NG/GM-113
Northgate Works
Access, egress and emergency response impairedObservation82025-12-12
R-PV-15
Working space around the vessel restricted
NG/PV-101
Northgate Works
Access, egress and emergency response impairedImprovement opportunity62026-08-27
R-PV-15
Working space around the vessel restrictedphoto
NG/PV-104
Northgate Works
Access, egress and emergency response impairedImprovement opportunity62026-04-29
R-PV-13
Pressure gauge missing or unreadable
LY/PV-106
Lyndale Packing
Uncontrolled release of stored pressureObservation62026-06-27
R-PV-15
Working space around the vessel restrictedphoto
HP/PV-108
Havenport Terminal
Access, egress and emergency response impairedImprovement opportunity62025-12-27
R-PV-13
Pressure gauge missing or unreadable
NG/PV-113
Northgate Works
Uncontrolled release of stored pressureObservation62026-06-27
R-SB-11
No single-line diagram at the board
LY/SB-103
Lyndale Packing
Loss of design or inspection traceabilityRecords / traceability62026-04-29
R-GM-17
Leak or product loss at the machinephoto
LY/GM-103
Lyndale Packing
Loss of containment to environmentObservation62026-02-27
R-GM-17
Leak or product loss at the machinephoto
HP/GM-105
Havenport Terminal
Loss of containment to environmentObservation62025-11-27
R-GM-17
Leak or product loss at the machinephoto
NG/GM-107
Northgate Works
Loss of containment to environmentObservation62026-06-27
R-GM-14
Walkway alongside the machine too narrow
NG/GM-110
Northgate Works
Access, egress and emergency response impairedImprovement opportunity62026-03-29
R-GM-14
Walkway alongside the machine too narrow
NG/GM-113
Northgate Works
Access, egress and emergency response impairedImprovement opportunity62026-01-27
R-GM-17
Leak or product loss at the machinephoto
NG/GM-113
Northgate Works
Loss of containment to environmentObservation62025-12-28
R-GM-13
Hazard or isolation signage missing
LY/GM-103
Lyndale Packing
Loss of design or inspection traceabilityImprovement opportunity42026-04-28
R-GM-13
Hazard or isolation signage missing
HP/GM-111
Havenport Terminal
Loss of design or inspection traceabilityImprovement opportunity42025-06-26
R-GM-13
Hazard or isolation signage missing
NG/GM-113
Northgate Works
Loss of design or inspection traceabilityImprovement opportunity42026-02-26