Plantsight
← Equipment register
Lyndale Packing · Packing hall

Infeed conveyor 103

Guarded machinery / conveyor · reassessed every 12 months · criticality A

Latest report
Current risk
Critical
Stop use, isolate, escalate to the responsible engineer
Open findings
5
highest score 20
Last assessed
2026-01-28
by M. Osei
Next due
2027-01-28
On schedule

Findings on the current assessment

from A-1059 · methodology v4.0
Fixed guard missingR-GM-01Immediate dangerfrom photoS5 × L4 = 20

A fixed guard is absent and the hazard it covered is reachable during normal operation.

Action Stop the machine and lock it out until the guard is refitted with tools-required fixings.

Entanglement or crushing at moving parts · due 2026-01-28 · AS 4024.1601 §5.2

Movable guard not interlockedR-GM-03Non-conformingS4 × L3 = 12

A guard that opens without a tool is not interlocked to the drive.

Action Fit a coded interlock to the movable guard and prove it stops the drive before the guard clears the hazard.

Entanglement or crushing at moving parts · due 2026-02-27 · ISO 14119 §5.1

Spillage or accumulation around the machineR-GM-15Observationfrom photoS2 × L4 = 8

Accumulated product or spillage is a slip hazard and hides developing faults.

Action Clean down and add the area to the shift housekeeping round.

Access, egress and emergency response impaired · due 2026-02-11 · ISO 12100 §6.2.7

Leak or product loss at the machineR-GM-17Observationfrom photoS2 × L3 = 6

Fluid loss is visible at a gland, gearbox or hydraulic joint.

Action Repair the leak and clean the area so the next assessment can distinguish new loss from old.

Loss of containment to environment · due 2026-02-27 · ISO 12100 §6.2.7

Hazard or isolation signage missingR-GM-13Improvement opportunityS1 × L4 = 4

The machine carries no hazard or isolation signage.

Action Fit signage at each access point covering the hazard and the isolation requirement.

Loss of design or inspection traceability · due 2026-04-28 · ISO 7010

Assessment history

2026-01-28 · M. Osei
A-1059 · assessed under v4.0 · 1 photo
5 findingsCriticalReport
2025-01-28 · J. Barros
A-1058 · assessed under v3.9
0 findingsLowReport
2024-01-28 · T. Fenwick
A-1057 · assessed under v3.9
1 findingHighReport

Historical assessments keep the methodology version they were completed under. Re-scoring old records against a newer version is an explicit action, never a side effect of publishing.

Asset record

Tag
LY/GM-103
Asset id
GM-103
Class
Guarded machinery / conveyor
Manufacturer
Lindmark
Model
S774
Serial
67673-75
Installed
2004-04-01
Facility
Lyndale Packing, Cranfield Way
Area
Packing hall
Facility manager
D. Petrov
Criticality
A

What this class is assessed on

  • Identification and records
    3 questions · photo + image analysis
  • Guarding
    5 questions · photo + image analysis
  • Emergency stop and isolation
    5 questions
  • Workplace
    3 questions

17 active rules · 8 vision cues.