← Equipment register
Northgate Works · Boiler house
Case erector 104
Guarded machinery / conveyor · reassessed every 12 months · criticality B
Current risk
High
Act before the equipment is next relied upon
Open findings
1
highest score 12
Last assessed
2025-10-28
by P. Nakamura
Next due
2026-10-28
On schedule
Findings on the current assessment
from A-1061 · methodology v4.0Emergency stop out of reachR-GM-06Non-conformingS4 × L3 = 12
An operator cannot reach an emergency stop from every working position.
Action Add stops or a pull-cord run so no working position is more than the methodology's distance from one.
Entanglement or crushing at moving parts · due 2025-11-11 · AS 4024.1601 §5.5
Assessment history
2025-10-28 · P. Nakamura
A-1061 · assessed under v4.0
2024-10-28 · J. Barros
A-1060 · assessed under v3.9
Historical assessments keep the methodology version they were completed under. Re-scoring old records against a newer version is an explicit action, never a side effect of publishing.
Asset record
- Tag
- NG/GM-104
- Asset id
- GM-104
- Class
- Guarded machinery / conveyor
- Manufacturer
- Vertek
- Model
- F952
- Serial
- 34885-84
- Installed
- 2010-09-01
- Facility
- Northgate Works, Ardmore Industrial Estate
- Area
- Boiler house
- Facility manager
- H. Vance
- Criticality
- B
What this class is assessed on
- Identification and records3 questions · photo + image analysis
- Guarding5 questions · photo + image analysis
- Emergency stop and isolation5 questions
- Workplace3 questions
17 active rules · 8 vision cues.