Plantsight
← Equipment register
Northgate Works · Boiler house

Case erector 104

Guarded machinery / conveyor · reassessed every 12 months · criticality B

Latest report
Current risk
High
Act before the equipment is next relied upon
Open findings
1
highest score 12
Last assessed
2025-10-28
by P. Nakamura
Next due
2026-10-28
On schedule

Findings on the current assessment

from A-1061 · methodology v4.0
Emergency stop out of reachR-GM-06Non-conformingS4 × L3 = 12

An operator cannot reach an emergency stop from every working position.

Action Add stops or a pull-cord run so no working position is more than the methodology's distance from one.

Entanglement or crushing at moving parts · due 2025-11-11 · AS 4024.1601 §5.5

Assessment history

2025-10-28 · P. Nakamura
A-1061 · assessed under v4.0
1 findingHighReport
2024-10-28 · J. Barros
A-1060 · assessed under v3.9
3 findingsHighReport

Historical assessments keep the methodology version they were completed under. Re-scoring old records against a newer version is an explicit action, never a side effect of publishing.

Asset record

Tag
NG/GM-104
Asset id
GM-104
Class
Guarded machinery / conveyor
Manufacturer
Vertek
Model
F952
Serial
34885-84
Installed
2010-09-01
Facility
Northgate Works, Ardmore Industrial Estate
Area
Boiler house
Facility manager
H. Vance
Criticality
B

What this class is assessed on

  • Identification and records
    3 questions · photo + image analysis
  • Guarding
    5 questions · photo + image analysis
  • Emergency stop and isolation
    5 questions
  • Workplace
    3 questions

17 active rules · 8 vision cues.