Plantsight
← Equipment register
Northgate Works · Line 4

Workshop jib hoist 104

Overhead travelling crane / hoist · reassessed every 6 months · criticality C

Latest report
Current risk
Moderate
Plan corrective work into the maintenance cycle
Open findings
2
highest score 9
Last assessed
2026-04-28
by P. Nakamura
Next due
2026-10-28
On schedule

Findings on the current assessment

from A-1047 · methodology v4.2
Major inspection overdueR-CR-14Non-conformingS3 × L3 = 9

The crane is outside its major inspection interval.

Action Book the major inspection with a competent person and plan the outage it needs.

Loss of design or inspection traceability · due 2026-06-27 · AS 2550.1 §5.5

Log book not currentR-CR-13Records / traceabilityS2 × L4 = 8

The crane log book does not carry the required entries, so service history cannot be evidenced.

Action Reconstruct the history from maintenance records and reinstate the log book at the crane.

Loss of design or inspection traceability · due 2026-05-28 · AS 2550.1 §5.3

Assessment history

2026-04-28 · P. Nakamura
A-1047 · assessed under v4.2
2 findingsModerateReport
2025-10-28 · J. Barros
A-1046 · assessed under v4.0
1 findingCriticalReport
2025-04-28 · M. Osei
A-1045 · assessed under v3.9
0 findingsLowReport

Historical assessments keep the methodology version they were completed under. Re-scoring old records against a newer version is an explicit action, never a side effect of publishing.

Asset record

Tag
NG/CR-104
Asset id
CR-104
Class
Overhead travelling crane / hoist
Manufacturer
Steelbridge Lifting
Model
N776
Serial
91916-31
Installed
2016-09-01
Facility
Northgate Works, Ardmore Industrial Estate
Area
Line 4
Facility manager
H. Vance
Criticality
C

What this class is assessed on

  • Identification and records
    4 questions · photo + image analysis
  • Hook and block
    4 questions · photo + image analysis
  • Rope, chain and reeving
    4 questions · photo + image analysis
  • Controls, limits and structure
    5 questions

17 active rules · 9 vision cues.