Infeed conveyor 107
Guarded machinery / conveyor · reassessed every 12 months · criticality C
Findings on the current assessment
from A-1066 · methodology v4.2A fixed guard is absent and the hazard it covered is reachable during normal operation.
Action Stop the machine and lock it out until the guard is refitted with tools-required fixings.
Entanglement or crushing at moving parts · due 2026-05-28 · AS 4024.1601 §5.2
Accumulated product or spillage is a slip hazard and hides developing faults.
Action Clean down and add the area to the shift housekeeping round.
Access, egress and emergency response impaired · due 2026-06-11 · ISO 12100 §6.2.7
Fluid loss is visible at a gland, gearbox or hydraulic joint.
Action Repair the leak and clean the area so the next assessment can distinguish new loss from old.
Loss of containment to environment · due 2026-06-27 · ISO 12100 §6.2.7
Assessment history
Historical assessments keep the methodology version they were completed under. Re-scoring old records against a newer version is an explicit action, never a side effect of publishing.
Asset record
- Tag
- NG/GM-107
- Asset id
- GM-107
- Class
- Guarded machinery / conveyor
- Manufacturer
- Preston Automation
- Model
- F621
- Serial
- 86707-18
- Installed
- 2013-06-01
- Facility
- Northgate Works, Ardmore Industrial Estate
- Area
- Line 4
- Facility manager
- H. Vance
- Criticality
- C
What this class is assessed on
- Identification and records3 questions · photo + image analysis
- Guarding5 questions · photo + image analysis
- Emergency stop and isolation5 questions
- Workplace3 questions
17 active rules · 8 vision cues.