Plantsight
NG/CR-104
Open assessment
Kestrel Process Group
Asset Integrity — equipment safety assessment

NG/CR-104

Workshop jib hoist 104

Report A-1047
Methodology v4.2
2026-04-28
Assessed risk
Moderate
Highest score
9
Findings
2
Immediate
0
Coverage
17/17
Next due
2026-10-28

Plan corrective work into the maintenance cycle

Asset class
Overhead travelling crane / hoist
Facility
Northgate Works, Ardmore Industrial Estate
Area
Line 4
Criticality
C
Manufacturer
Steelbridge Lifting
Model / serial
N776 / 91916-31
Installed
2016-09-01
Inspector
P. Nakamura

Findings (2)

R-CR-14Major inspection overdueNon-conformingS3 × L3 = 9Moderate

The crane is outside its major inspection interval.

Action Book the major inspection with a competent person and plan the outage it needs.

Loss of design or inspection traceability · due 2026-06-27 · AS 2550.1 §5.5

R-CR-13Log book not currentRecords / traceabilityS2 × L4 = 8Moderate

The crane log book does not carry the required entries, so service history cannot be evidenced.

Action Reconstruct the history from maintenance records and reinstate the log book at the crane.

Loss of design or inspection traceability · due 2026-05-28 · AS 2550.1 §5.3

Assessment record

Identification and records · Is the safe working load marked and legible?Yes
Identification and records · Marked safe working load9579 kg
Identification and records · Is the crane log book current?No
Identification and records · Months since last major inspection26 months
Hook and block · Is the hook safety latch fitted and effective?Yes
Hook and block · Throat opening increase over as-new4 %
Hook and block · Is the hook free of twist, cracking or gouging?Yes
Hook and block · Does the block rotate and seat freely?Yes
Rope, chain and reeving · Broken wires in any one rope lay0 wires
Rope, chain and reeving · Rope deformationNone
Rope, chain and reeving · Is the rope adequately lubricated and free of corrosion?Yes
Rope, chain and reeving · Are the rope terminations correct and secure?Yes
Controls, limits and structure · Does the upper hoist limit operate on test?Yes
Controls, limits and structure · Does the emergency stop isolate all motions?Yes
Controls, limits and structure · Does the hoist brake hold the test load without creep?Yes
Controls, limits and structure · Are travel end stops and buffers in place and undamaged?Yes
Controls, limits and structure · Pendant / control conditionWorn but legible

The PDF is generated server-side from this same data — same findings, same wording, same methodology version, plus the photo plate and a sign-off block.