Plantsight
NG/GM-110
Open assessment
Kestrel Process Group
Asset Integrity — equipment safety assessment

NG/GM-110

Trim press 110

Report A-1070
Methodology v4.0
2026-01-28
Assessed risk
High
Highest score
12
Findings
3
Immediate
0
Coverage
16/16
Next due
2027-01-28

Act before the equipment is next relied upon

Asset class
Guarded machinery / conveyor
Facility
Northgate Works, Ardmore Industrial Estate
Area
Goods in
Criticality
A
Manufacturer
Preston Automation
Model / serial
V411 / 53589-55
Installed
2004-05-01
Inspector
J. Barros

Findings (3)

R-GM-07Pull-cord fails along part of its runNon-conformingS4 × L3 = 12High

The pull-cord does not stop the machine from every point along the conveyor.

Action Re-tension the cord, replace the failed switch, and prove a stop from each end and the mid-point.

Entanglement or crushing at moving parts · due 2026-02-04 · ISO 13850 §4.4

R-GM-11No current risk assessment on fileRecords / traceabilityS2 × L4 = 8Moderate

No risk assessment is held for the machine in its current configuration.

Action Complete a machine risk assessment and file it against the asset number.

Loss of design or inspection traceability · due 2026-03-29 · ISO 12100 §5

R-GM-14Walkway alongside the machine too narrowImprovement opportunityS2 × L3 = 6Moderate

The walkway beside the machine is narrower than the methodology allows.

Action Widen or re-route the walkway, or barrier it off if the width cannot be achieved.

Access, egress and emergency response impaired · due 2026-03-29 · ISO 14122-2 §4.2

Assessment record

Identification and records · Is a current risk assessment on file for this machine?No
Identification and records · Is the manufacturer's manual available on site?Yes
Identification and records · Has the machine been modified since commissioning?No
Guarding · Are all fixed guards present and secured with tools-required fixings?Yes
Guarding · Are movable guards interlocked?Yes
Guarding · Is any interlock bypassed, taped or defeated?No
Guarding · Are in-running nips and drives guarded?Yes
Guarding · Largest gap in guarding5 mm
Emergency stop and isolation · Furthest distance from any operating position to an emergency stop1.6 m
Emergency stop and isolation · Does the pull-cord stop the machine from every point along its run?No
Emergency stop and isolation · Does restart require a deliberate reset at the machine?Yes
Emergency stop and isolation · Is the isolation / lockout point identified and lockable?Yes
Emergency stop and isolation · Are all stored energy sources documented for isolation?Yes
Workplace · Is hazard and isolation signage in place?Yes
Workplace · Clear walkway width alongside the machine560 mm
Workplace · Housekeeping around the machineMinor debris

The PDF is generated server-side from this same data — same findings, same wording, same methodology version, plus the photo plate and a sign-off block.