NG/GM-107
Infeed conveyor 107
Stop use, isolate, escalate to the responsible engineer
Findings (3)
A fixed guard is absent and the hazard it covered is reachable during normal operation.
Action Stop the machine and lock it out until the guard is refitted with tools-required fixings.
Entanglement or crushing at moving parts · due 2026-05-28 · AS 4024.1601 §5.2 · evidence VC-MISSING-GUARD
Accumulated product or spillage is a slip hazard and hides developing faults.
Action Clean down and add the area to the shift housekeeping round.
Access, egress and emergency response impaired · due 2026-06-11 · ISO 12100 §6.2.7 · evidence VC-HOUSEKEEPING
Fluid loss is visible at a gland, gearbox or hydraulic joint.
Action Repair the leak and clean the area so the next assessment can distinguish new loss from old.
Loss of containment to environment · due 2026-06-27 · ISO 12100 §6.2.7 · evidence VC-LEAK
Photographic record

Illustration of a conveyor drive end with an open gearbox/belt-and-pulley drive on a green frame at left, a yellow mesh guard panel mid-span, an E-stop pull-cord with red button along the top, and a brown fluid pool on the floor beneath the drive.
- Leak, drip or product staining — A brown/amber pool with scattered droplets sits under the drive, with a dark line running down from the underside of the blue gearbox/motor into the pool.
- Guard removed or rotating part exposed — Drive pulleys, belt and gear wheel are fully visible in the open within a black-backed frame with bolt holes/fixings at each corner and along the edges, no cover panel fitted.
- Housekeeping around the asset — Spilled liquid pool roughly 1 m across with scattered droplet spatter spreading across the floor slab.
Assisted by claude-opus-5; every observation adjudicated by the inspector before use.
Assessment record