Kestrel Process Group
Asset Integrity — equipment safety assessment
HP/GM-102
Case erector 102
Report A-1056
Methodology v3.9
2025-05-28
Assessed risk
High
Highest score
12
Findings
2
Immediate
0
Coverage
16/16
Next due
2026-05-28
Act before the equipment is next relied upon
Asset class
Guarded machinery / conveyor
Facility
Havenport Terminal, Dock Road
Area
Packing hall
Criticality
A
Manufacturer
Lindmark
Model / serial
V946 / 44948-26
Installed
2007-03-01
Inspector
P. Nakamura
Findings (2)
R-GM-06Emergency stop out of reachNon-conformingS4 × L3 = 12High
An operator cannot reach an emergency stop from every working position.
Action Add stops or a pull-cord run so no working position is more than the methodology's distance from one.
Entanglement or crushing at moving parts · due 2025-06-11 · AS 4024.1601 §5.5
R-GM-10Stored energy sources not documentedRecords / traceabilityS3 × L3 = 9Moderate
Stored energy is not documented, so isolation cannot be verified as complete.
Action Walk the machine with the maintainer, list every energy source, and publish it at the isolation point.
Loss of design or inspection traceability · due 2025-06-27 · ISO 14118 §6
Assessment record
Identification and records · Is a current risk assessment on file for this machine?Yes
Identification and records · Is the manufacturer's manual available on site?Yes
Identification and records · Has the machine been modified since commissioning?No
Guarding · Are all fixed guards present and secured with tools-required fixings?Yes
Guarding · Are movable guards interlocked?Yes
Guarding · Is any interlock bypassed, taped or defeated?No
Guarding · Are in-running nips and drives guarded?Yes
Guarding · Largest gap in guarding6 mm
Emergency stop and isolation · Furthest distance from any operating position to an emergency stop3.7 m
Emergency stop and isolation · Does the pull-cord stop the machine from every point along its run?Yes
Emergency stop and isolation · Does restart require a deliberate reset at the machine?Yes
Emergency stop and isolation · Is the isolation / lockout point identified and lockable?Yes
Emergency stop and isolation · Are all stored energy sources documented for isolation?No
Workplace · Is hazard and isolation signage in place?Yes
Workplace · Clear walkway width alongside the machine1051 mm
Workplace · Housekeeping around the machineClean
The PDF is generated server-side from this same data — same findings, same wording, same methodology version, plus the photo plate and a sign-off block.