LY/CR-106
Boiler house crane 106
Stop use, isolate, escalate to the responsible engineer
Findings (2)
Rope condition meets the discard criteria in the methodology.
Action Take the crane out of service and replace the rope as an assembly, with a certificate for the new rope.
Dropped or swinging load · due 2026-07-28 · ISO 4309 §5.2 · evidence VC-ROPE-DAMAGE
Corrosion or lack of lubrication is degrading the rope faster than the inspection interval assumes.
Action Clean and dress the rope with the manufacturer's lubricant and shorten the inspection interval until the trend stops.
Dropped or swinging load · due 2026-08-11 · ISO 4309 §5.5 · evidence VC-CORR-HEAVY
Photographic record

An illustration of an overhead crane hook block hanging on two wire ropes, with a single hook and safety latch, showing rust-coloured patches on the block, ropes and hook.
- Heavy corrosion or section loss — Large irregular orange-brown flaking patches spread across the block casing edge and across the hook bowl, covering a substantial area of those surfaces; texture appears as scale rather than light staining. Section loss cannot be measured from the image.
- Light surface corrosion or coating breakdown — Smaller rust-brown bloom on the left rope leg and light staining around the SWL marking on the block face.
- Rope or chain damage — Two or three short curved wire strands stand proud of the rope surface, consistent with broken wires.
Assisted by claude-opus-5; every observation adjudicated by the inspector before use.
Assessment record
The PDF is generated server-side from this same data — same findings, same wording, same methodology version, plus the photo plate and a sign-off block.