Plantsight
LY/CR-106
Open assessment
Kestrel Process Group
Asset Integrity — equipment safety assessment

LY/CR-106

Boiler house crane 106

Report A-1050
Methodology v4.2
2026-07-28
Assessed risk
Critical
Highest score
15
Findings
2
Immediate
1
Coverage
17/17
Next due
2027-01-27

Stop use, isolate, escalate to the responsible engineer

Asset class
Overhead travelling crane / hoist
Facility
Lyndale Packing, Cranfield Way
Area
Boiler house
Criticality
A
Manufacturer
Steelbridge Lifting
Model / serial
G794 / 25038-97
Installed
2015-11-01
Inspector
R. Aldridge

Findings (2)

R-CR-05Broken wires at or beyond discard criteriaImmediate dangerphotographic evidenceS5 × L3 = 15Critical

Rope condition meets the discard criteria in the methodology.

Action Take the crane out of service and replace the rope as an assembly, with a certificate for the new rope.

Dropped or swinging load · due 2026-07-28 · ISO 4309 §5.2 · evidence VC-ROPE-DAMAGE

R-CR-07Rope corroded or unlubricatedNon-conformingphotographic evidenceS3 × L3 = 9Moderate

Corrosion or lack of lubrication is degrading the rope faster than the inspection interval assumes.

Action Clean and dress the rope with the manufacturer's lubricant and shorten the inspection interval until the trend stops.

Dropped or swinging load · due 2026-08-11 · ISO 4309 §5.5 · evidence VC-CORR-HEAVY

Photographic record

Site photograph taken at assessment
Site photograph taken at assessment

An illustration of an overhead crane hook block hanging on two wire ropes, with a single hook and safety latch, showing rust-coloured patches on the block, ropes and hook.

  • Heavy corrosion or section lossLarge irregular orange-brown flaking patches spread across the block casing edge and across the hook bowl, covering a substantial area of those surfaces; texture appears as scale rather than light staining. Section loss cannot be measured from the image.
  • Light surface corrosion or coating breakdownSmaller rust-brown bloom on the left rope leg and light staining around the SWL marking on the block face.
  • Rope or chain damageTwo or three short curved wire strands stand proud of the rope surface, consistent with broken wires.

Assisted by claude-opus-5; every observation adjudicated by the inspector before use.

Assessment record

Identification and records · Is the safe working load marked and legible?Yes
Identification and records · Marked safe working load3596 kg
Identification and records · Is the crane log book current?Yes
Identification and records · Months since last major inspection8 months
Hook and block · Is the hook safety latch fitted and effective?Yes
Hook and block · Throat opening increase over as-new0 %
Hook and block · Is the hook free of twist, cracking or gouging?Yes
Hook and block · Does the block rotate and seat freely?Yes
Rope, chain and reeving · Broken wires in any one rope lay0 wires
Rope, chain and reeving · Rope deformationMinor
Rope, chain and reeving · Is the rope adequately lubricated and free of corrosion?Yes
Rope, chain and reeving · Are the rope terminations correct and secure?Yes
Controls, limits and structure · Does the upper hoist limit operate on test?Yes
Controls, limits and structure · Does the emergency stop isolate all motions?Yes
Controls, limits and structure · Does the hoist brake hold the test load without creep?Yes
Controls, limits and structure · Are travel end stops and buffers in place and undamaged?Yes
Controls, limits and structure · Pendant / control conditionSound

The PDF is generated server-side from this same data — same findings, same wording, same methodology version, plus the photo plate and a sign-off block.