Plantsight
NG/PV-113
Open assessment
Kestrel Process Group
Asset Integrity — equipment safety assessment

NG/PV-113

Air receiver 113

Report A-1023
Methodology v4.2
2026-05-28
Assessed risk
Moderate
Highest score
8
Findings
3
Immediate
0
Coverage
18/18
Next due
2027-05-28

Plan corrective work into the maintenance cycle

Asset class
Pressure vessel / air receiver
Facility
Northgate Works, Ardmore Industrial Estate
Area
Compressor house
Criticality
B
Manufacturer
Enerfab
Model / serial
A522 / 68313-37
Installed
2006-03-01
Inspector
M. Osei

Findings (3)

R-PV-10Data plate missing or unreadableRecords / traceabilityS2 × L4 = 8Moderate

The vessel cannot be traced to its registered design data from markings on the equipment.

Action Recover the design registration from the plant register and fit a durable replacement plate carrying the registration number and MAWP.

Loss of design or inspection traceability · due 2026-07-27 · AS/NZS 3788 §4.4

R-PV-14Drain inoperable or condensate presentObservationS2 × L4 = 8Moderate

Condensate cannot be drained, which drives internal corrosion at the bottom of the shell.

Action Free or replace the drain and add a daily drain check to the operator round.

Structural failure under load · due 2026-06-27 · API 510 §6.4

R-PV-13Pressure gauge missing or unreadableObservationS2 × L3 = 6Moderate

Operating pressure cannot be read at the vessel.

Action Fit a gauge spanning at least 1.5 times MAWP and mark the normal operating range on the dial.

Uncontrolled release of stored pressure · due 2026-06-27 · AS/NZS 3788 §5.7

Assessment record

Identification and records · Is the manufacturer's data plate present and legible?No
Identification and records · Design registration / plant numberPVR-68313
Identification and records · Maximum allowable working pressure1021 kPa
Identification and records · Months since last internal inspection18 months
Identification and records · Is the pressure test within its interval?Yes
Pressure relief · Is a pressure relief device fitted?Yes
Pressure relief · Is the set pressure at or below MAWP?Yes
Pressure relief · Months since relief device certification12 months
Pressure relief · Discharge pathClear to safe area
Pressure relief · Is an isolation valve fitted between the vessel and the relief device?No
External condition · External corrosionNone
External condition · Are the visible weld seams free of cracking or undercut?Yes
External condition · Saddle and support conditionSound
External condition · Is the drain operable and the vessel free of standing condensate?No
Instrumentation and surrounds · Is a pressure gauge fitted and readable?No
Instrumentation and surrounds · Is the isolation point identified and accessible?Yes
Instrumentation and surrounds · Clear working space around the vessel1414 mm
Instrumentation and surrounds · Is required signage in place?Yes

The PDF is generated server-side from this same data — same findings, same wording, same methodology version, plus the photo plate and a sign-off block.