Plantsight
LY/GM-106
Open assessment
Kestrel Process Group
Asset Integrity — equipment safety assessment

LY/GM-106

Bagging machine 106

Report A-1064
Methodology v4.2
2026-04-28
Assessed risk
High
Highest score
12
Findings
1
Immediate
0
Coverage
16/16
Next due
2027-04-28

Act before the equipment is next relied upon

Asset class
Guarded machinery / conveyor
Facility
Lyndale Packing, Cranfield Way
Area
Dispatch
Criticality
A
Manufacturer
Lindmark
Model / serial
N293 / 46717-98
Installed
2010-10-01
Inspector
J. Barros

Findings (1)

R-GM-05Guard aperture exceeds safe gapNon-conformingS4 × L3 = 12High

A gap in the guarding allows a hand to reach the hazard at the measured distance.

Action Close the aperture or move the guard back until the safe-distance table is satisfied.

Entanglement or crushing at moving parts · due 2026-05-12 · ISO 13857 §4.2

Assessment record

Identification and records · Is a current risk assessment on file for this machine?Yes
Identification and records · Is the manufacturer's manual available on site?Yes
Identification and records · Has the machine been modified since commissioning?No
Guarding · Are all fixed guards present and secured with tools-required fixings?Yes
Guarding · Are movable guards interlocked?Yes
Guarding · Is any interlock bypassed, taped or defeated?No
Guarding · Are in-running nips and drives guarded?Yes
Guarding · Largest gap in guarding41 mm
Emergency stop and isolation · Furthest distance from any operating position to an emergency stop1.3 m
Emergency stop and isolation · Does the pull-cord stop the machine from every point along its run?Yes
Emergency stop and isolation · Does restart require a deliberate reset at the machine?Yes
Emergency stop and isolation · Is the isolation / lockout point identified and lockable?Yes
Emergency stop and isolation · Are all stored energy sources documented for isolation?Yes
Workplace · Is hazard and isolation signage in place?Yes
Workplace · Clear walkway width alongside the machine1193 mm
Workplace · Housekeeping around the machineClean