Kestrel Process Group
Asset Integrity — equipment safety assessment
LY/PV-109
Nitrogen buffer vessel 109
Report A-1016
Methodology v3.9
2025-04-28
Assessed risk
Low
Highest score
0
Findings
0
Immediate
0
Coverage
18/18
Next due
2026-04-28
Monitor at next scheduled assessment
Asset class
Pressure vessel / air receiver
Facility
Lyndale Packing, Cranfield Way
Area
Line 2
Criticality
A
Manufacturer
Wessex Vessels
Model / serial
U944 / 75223-15
Installed
2004-02-01
Inspector
J. Barros
Findings (0)
No rule in methodology v3.9 was triggered by the recorded answers or accepted photographic evidence.
Assessment record
Identification and records · Is the manufacturer's data plate present and legible?Yes
Identification and records · Design registration / plant numberPVR-75223
Identification and records · Maximum allowable working pressure900 kPa
Identification and records · Months since last internal inspection44 months
Identification and records · Is the pressure test within its interval?Yes
Pressure relief · Is a pressure relief device fitted?Yes
Pressure relief · Is the set pressure at or below MAWP?Yes
Pressure relief · Months since relief device certification24 months
Pressure relief · Discharge pathClear to safe area
Pressure relief · Is an isolation valve fitted between the vessel and the relief device?No
External condition · External corrosionLight
External condition · Are the visible weld seams free of cracking or undercut?Yes
External condition · Saddle and support conditionSurface corrosion
External condition · Is the drain operable and the vessel free of standing condensate?Yes
Instrumentation and surrounds · Is a pressure gauge fitted and readable?Yes
Instrumentation and surrounds · Is the isolation point identified and accessible?Yes
Instrumentation and surrounds · Clear working space around the vessel1451 mm
Instrumentation and surrounds · Is required signage in place?Yes
The PDF is generated server-side from this same data — same findings, same wording, same methodology version, plus the photo plate and a sign-off block.