Plantsight
NG/PV-107
Open assessment
Kestrel Process Group
Asset Integrity — equipment safety assessment

NG/PV-107

Instrument air receiver 107

Report A-1012
Methodology v4.0
2025-06-28
Assessed risk
Low
Highest score
0
Findings
0
Immediate
0
Coverage
18/18
Next due
2026-06-28

Monitor at next scheduled assessment

Asset class
Pressure vessel / air receiver
Facility
Northgate Works, Ardmore Industrial Estate
Area
Dispatch
Criticality
B
Manufacturer
Wessex Vessels
Model / serial
T262 / 24029-57
Installed
2021-01-01
Inspector
P. Nakamura

Findings (0)

No rule in methodology v4.0 was triggered by the recorded answers or accepted photographic evidence.

Assessment record

Identification and records · Is the manufacturer's data plate present and legible?Yes
Identification and records · Design registration / plant numberPVR-24029
Identification and records · Maximum allowable working pressure1156 kPa
Identification and records · Months since last internal inspection24 months
Identification and records · Is the pressure test within its interval?Yes
Pressure relief · Is a pressure relief device fitted?Yes
Pressure relief · Is the set pressure at or below MAWP?Yes
Pressure relief · Months since relief device certification38 months
Pressure relief · Discharge pathClear to safe area
Pressure relief · Is an isolation valve fitted between the vessel and the relief device?No
External condition · External corrosionNone
External condition · Are the visible weld seams free of cracking or undercut?Yes
External condition · Saddle and support conditionSound
External condition · Is the drain operable and the vessel free of standing condensate?Yes
Instrumentation and surrounds · Is a pressure gauge fitted and readable?Yes
Instrumentation and surrounds · Is the isolation point identified and accessible?Yes
Instrumentation and surrounds · Clear working space around the vessel1084 mm
Instrumentation and surrounds · Is required signage in place?Yes